Disposal - Dometic HIPRO A30 Operating Manual

Minibar
Hide thumbs Also See for HIPRO A30:
Table of Contents

Advertisement

Available languages

Available languages

Dometic HiPro Apollo, Evolution
Problem
Frost formation in the minibar com-
partment
Interior lighting is not working

10 Disposal

WARNING! Fire hazard
• The refrigerant is highly flammable. Do not open or damage the refrigerant circuit.
• The insulation of the device contains an insulating gas (see data plate). Do not damage the insula-
tion.
Recycling packaging material: Place the packaging material in the appropriate recycling waste bins wher-
ever possible.
Recycling products with non-replaceable batteries, rechargeable batteries or light sources:
• If the product contains any non-replaceable batteries, rechargeable batteries or light sources, you
don't have to remove them before disposal.
• If you wish to finally dispose of the product, ask your local recycling center or specialist dealer for
details about how to do this in accordance with the applicable disposal regulations.
• The product can be disposed free of charge.
Possible cause
Door of minibar is not closed with a
tight seal.
Minibar recently filled.
For versions with absorber cool-
ing: The input voltage is too low or
too high.
Door of minibar is not closed with a
tight seal.
Power plug is not plugged in.
Interior lighting is defective.
Surface of infrared door sensor is cov-
ered by condensation.
Suggested remedy
Check distances (see Installation Man-
ual).
Contact an authorized service
agent.
Service agent only: Replace
door seal
Check cooling again after 5 h ... 6 h.
Check input voltage.
Check distances (see Installation Man-
ual).
Contact an authorized service
agent.
Service agent only: Replace
door seal
Insert the power plug into the socket.
Contact an authorized service
agent.
Service agent only: Change
interior lighting
Clean the surface of the infrared door
sensor.
EN
15

Advertisement

Table of Contents
loading