System indication
Operating status
System is normally operat-
ing
Cooling water circulation
flow passage is clogged
Cooling water temperature
exceeds 60 degrees
Circulation pump has failed
Water shortage alarm

5-5. Adjusting the laser

If it is necessary to adjust the light path, be sure to contact our After-Sale Service staff
before carrying out the adjustment. The professional staff who has received professional
training in JUKI to gain experience of the relevant adjustment work will carry out the ad-
justment.
1) Laser switch key
Do not pull out the laser switch key.
When the switch is set to "1", the laser is energized and can be operated.
When the switch is set to "0", the power to the laser is disconnected and the laser cannot be operat-
ed. However, even in this case, the sewing machine is able to perform sewing.
Green lamp
Red lamp
Light up
Goes out
Goes out
Light up
Goes out
Light up
Goes out
Light up
Goes out
Light up
Fig. 3
– 21 –
5-4-3. Pilot lamp of the cooling
system
Buzzer
1) Pilot lamp: Fig. 3
* Refer to the "Explanations
Silent
about handling / installation of
industrial cooling system" for
Sound is
the detailed description of how
generated
to handle the cooling system.
Sound is
generated
Sound is
generated
Sound is
generated