4.6.3 Determining which temperature control you are using

ETVZ16S18+23DA6V+9W
Daikin Altherma 3 H HT F
4P586461-1A – 2020.01
2 Select one of the following options:
Heating: Only heating mode
Cooling: Only cooling mode
Automatic: The operation mode changes automatically
based on the outdoor temperature. Restricted according to
the operation mode schedule.
Automatic heating/cooling changeover is NOT applicable for heating only models.
When Automatic is selected, the changing of the operation mode is based on the
Operation mode schedule [4.2].
To restrict automatic changeover according to a schedule
Conditions: You set the space operation mode to Automatic.
1 Go to [4.2]: Space heating/cooling > Operation mode
schedule.
2 Select a month.
3 For each month, select an option:
Reversible: Not restricted
Heating only: Restricted
Cooling only: Restricted
4 Confirm the changes.
Example: Changeover restrictions
When
During cold season.
Example: October, November, December, January,
February and March.
During warm season.
Example: June, July and August.
In-between.
Example: April, May and September.
If both the Operation mode and the Operation mode schedule are set to
Automatic, the operation mode will be determined by the outdoor temperature.
To determine which temperature control you are using (method 1)
Check the installer settings table filled in by the installer.
To determine which temperature control you are using (method 2)
You can see on the home screen which temperature control you are using.
4
Operation
|
Restriction
Heating only
Cooling only
Heating/Cooling