(5) Corrective actions
When it is assumed that a hazardous condition may take place at the occur due to a power
failure or a product fault,, use a servo motor with electromag<->netic brake or an external
brake mechanism for the purpose of prevention.
Configure the electromagnetic brake circuit so that it is activated not only by the servo
amplifier signals but also by an external emergency stop signal.
When any alarm has occurred,, eliminate its cause,, ensure safety,, then reset the alarm,,
before restarting operation.
When power is restored after an instantaneous power failure,, keep away from the ma-
chine because the machine may be restarted suddenly (design the machine so that it is
secured against hazard if restarted).
(6) Maintenance, inspection and parts replacement
With age, the electrolytic capacitor will deteriorate. To prevent a secondary accident due
to a fault, it is recommended to replace the electrolytic capacitor every 10 years when
used in general environment.
Please consult our sales representative.
(7) Disposal
Dispose of the product as general industrial waste.
(8) General instruction
To illustrate details, the equipment in the diagrams of this Installation guide may have been
drawn without covers and safety guards. When the equipment is operated, the covers and safety
guards must be installed as specified. Operation must be performed in accordance with this
Installation guide.
CAUTION
Contacts must be
open when servo
is off or when an
alarm (trouble) is
present.
Servo motor
Electromagnetic brake
CAUTION
CAUTION
– 6 –
C i r c u i t m u s t b e
o p e n e d
d u r i n g
emergency stop.
EMG
RA1
24VDC