Ec Declaration Of Conformity (Original); Confirmation Of Cip Testing; Health And Safety Of The Operator - Hilti DX 35 Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

This constitutes Hilti's entire obligation with regard to
warranty and supersedes all prior or contemporaneous

13 EC declaration of conformity (original)

Designation:
Type:
Generation:
Year of design:
We declare, on our sole responsibility, that this product
complies with the following directives and standards:
2006/42/EC, 2011/65/EU.

14 Confirmation of CIP testing

The following applies to C.I.P. member states outside
the EU and EFTA judicial area: The Hilti DX 35 has been
system and type tested. As a result, the tool bears the
rectangular PTB approval mark showing approval num-
ber S 806. Hilti thus guarantees compliance with the ap-

15 Health and safety of the operator

15.1 Noise information
Powder-actuated fastening tool
Type
Model
Caliber
Application
Declared measured values of noise characteristics according to 2006/42/EC Machinery Directive in conjunction
with DIN EN 15895
Noise (power) level, L
WA, 1S
Emission noise-pressure level in the work station,
L
2
pA, 1s
Peak sound pressure emission level, L
1 ± 2 dB (A)
2 ± 2 dB (A)
3 ± 2 dB (C)
Powder-actuated fasten-
ing tool
DX 35
01
1976
1
3
pC, peak
comments and oral or written agreements concerning
warranties.
Hilti Corporation, Feldkircherstrasse 100,
FL‑9494 Schaan
Norbert Wohlwend
Head of Quality & Processes Manage-
ment
BU Direct Fastening
04/2013
Technical documentation filed at:
Hilti Entwicklungsgesellschaft mbH
Zulassung Elektrowerkzeuge
Hiltistrasse 6
86916 Kaufering
Deutschland
proved type. Unacceptable defects or deficiencies, etc.
determined during use of the tool must be reported to the
person responsible at the approval authority (PTB) and
to the Office of the Permanent International Commission
(C.I.P.).
DX 35
Series
6.3/10 yellow
Fastening 1 mm sheet steel to concrete (C40) with the
X-U22 P8
The tool has no power regulation feature.
113 dB (A)
109 dB (A)
142 dB (C)
en
Tassilo Deinzer
Head BU Measuring Systems
BU Measuring Systems
04/2013
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents