Technical Data; Piping Diagram: Indoor Unit - Daikin ETVH-D9WG Installation Manual

Hide thumbs Also See for ETVH-D9WG:
Table of Contents

Advertisement

9

Technical data

A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is
available on the Daikin Business Portal (authentication required).
9.1

Piping diagram: Indoor unit

A
B
a2
f
l
b2
b1
B
a1
f
l
A
Indoor unit
B
Field installed
a1
Space heating water IN
a2
Space heating water OUT
b1
Domestic hot water: cold water IN, loose nut 3/4"
b2
Domestic hot water: hot water OUT, loose nut 3/4"
c1
Water IN connection
c2
Water OUT connection
d
Pump
e
Backup heater
f
Shut-off valve, male-female 1"
g
Expansion vessel
h
Magnetic filter/dirt separator
i
Safety valve
j
Air purge
k
Drain valve
l
Loose nut 1"
B1L
Flow sensor
B1PW
Space heating water pressure sensor
M3S
3-way valve (space heating/domestic hot water)
R1T
Thermistor (water IN)
R2T
Thermistor (backup heater – water OUT)
R5T, R8T
Thermistor (tank)
S1L
Flow switch
Screw connection
Flare connection
Quick coupling
Brazed connection
ETVH/X16S18+23DA6V+9W(G)
Daikin Altherma 3 H HT F
4P586454-1B – 2020.01
j
R2T
e
k
M3S
R8T
R5T
g
B1PW
S1L
B1L
R1T
i
j
d
h
k
k
9 Technical data
B
c1
l
f
B
c2
f
l
3D120611A