7. After a successful setup, click Continue.
Your browser automatically redirects to the Management IP address of the array.
Note: If the array does not initialize, check the cabling to the network switch and check the subnet mask.
8. In the login screen, type the password you set and click Log In.
From this point forward, you are in the operating system GUI.
9. Provide the Subnet Configuration information for the following sections and click Next:
a) Management IP:
IP address
Network
Subnet mask
Note: The Management IP is used for the GUI, CLI, and replication. It resides on the management subnet and
floats across all "Mgmt only" and "Mgmt + Data" interfaces on that subnet.
b) Subnet:
Subnet label
Network
Netmask
Traffic Type – Data only
Traffic Assignment (This field is hidden if you are running a Fibre Channel array)
Discovery IP (This field is hidden if you are running a Fibre Channel array)
IP Address Zone – Single, Bisect, or Even/Odd (This field is hidden if you are running a Fibre Channel array)
Maximum Transmission Unit (MTU) – Standard, Jumbo, or Custom
Frame size in bytes – User specified value
Ensure that your network switches support the selected frame size.
Note: If Jumbo frames are selected, ensure that they are configured end to end. To confirm that Jumbo
frames are supported, perform an end-to-end ping with the jumbo frame size and without fragmentation;
for example: ping <hostname> -f -l 8972
The data port IP addresses are assigned to interface pairs, such as eth5 on controller A and eth5 on controller B.
If one controller fails, the corresponding port on the remaining controller still has data access. At least one interface
pair must be configured. However, a minimum of two is recommended.
Note: To add a data subnet, click Add Data Subnet, provide the required information.
10. Provide Interface Assignment information for the following sections and click Next:
a) Interface Assignment:
For each IP interface, assign a subnet and a Data IP address within the specified network. For inactive interfaces, assign
the "None" subnet.
b) FC Interface (Fibre Channel arrays only):
This section displays the link status for all Fibre Channel ports. No configuration is required.
c) Diagnostic IP:
Controller A diagnostic IP address within the specified network
Controller B diagnostic IP address within the specified network
11. Provide the following Domain information and click Next:
a) Domain Name
Documentation Feedback: doc-feedback-hpe-storage@hpe.com