If you remove a key, use a specially designed key puller to prevent damage to the keys. This tool is
available through many electronic supply outlets.
CAUTION:
improperly removed or installed, the keyboard may not function properly.
Cleaning under a key may be done with a swab moistened with isopropyl alcohol and squeezed out. Be
careful not to wipe away lubricants necessary for proper key functions. Use tweezers to remove any
fibers or dirt in confined areas. Allow the parts to air dry before reassembly.

Cleaning the display

Wipe the display screen with a clean cloth moistened with water or with a towelette designed for
cleaning displays. Do not use sprays or aerosols directly on the screen; the liquid may seep into the
housing and damage a component. Never use solvents or flammable liquids on the display.
To clean the display body follow the procedures in

Cleaning the mouse

Before cleaning the mouse, ensure that the power to the computer is turned off.
Clean the mouse ball by first removing the retaining plate and the ball from the housing. Pull out any
debris from the ball socket and wipe the ball with a clean, dry cloth before reassembly.
To clean the mouse body, follow the procedures in

Service considerations

Listed below are some of the considerations that you should keep in mind during the disassembly and
assembly of the computer.

Tools and software requirements

To service the computer, you need the following:
Torx T-15 screwdriver
Flat-bladed screwdriver (may sometimes be used in place of the Torx screwdriver)
Phillips #2 screwdriver

Screws

The screws used in the computer are not interchangeable. They may have standard or metric threads and may
be of different lengths. If an incorrect screw is used during the reassembly process, it can damage the unit. HP
strongly recommends that all screws removed during disassembly be kept with the part that was removed,
then returned to their proper locations.
CAUTION:
CAUTION:
to prevent damage.

Cables and connectors

Most cables used throughout the unit are flat, flexible cables. These cables must be handled with care to
avoid damage. Apply only the tension required to seat or unseat the cables during insertion or removal from
18
Chapter 3 Routine care, SATA drive guidelines, and disassembly preparation
Never remove a wide leveled key (like the space bar) from the keyboard. If these keys are
Metric screws have a black finish. U.S. screws have a silver finish and are used on hard drives only.
As each subassembly is removed from the computer, it should be placed away from the work area
Cleaning the Computer Case on page
Cleaning the Computer Case on page
17.
17.