Top Vent DVP-TRAP1 Exception
For installations that are top vented and horizontally terminated with a 90 degree elbow directly off the appliance
and minimum vent run, a termination cap with effective length equal to the DVP-TRAP1 is REQUIRED. Interior and
exterior wall sheathing 1/2 inch thick and 2 X 4 exterior wall studs are also assumed for this scenario.
SHEATHING 1/2 IN. THICK
4-1/2 IN.
2 X 4
(3-1/2 IN.)
Figure 3.9 DVP-TRAP1 Exception (2 x 4 Construction)
EXTERIOR
BACK OF APPLIANCE TO
WALL SHEATHING
INTERIOR SHEATHING
1/2 IN. THICK
DVP90ST
Majestic • MER36MN, MER42MN Installation Manual • 2599-980 Rev. B • 5/23
1/2 IN. MIN.
CLEARANCE
5 IN. MIN
I* = 5 INCHES TO
FRONT OF DVP-TRAP1
TERMINATION CAP
19