1.2

Specialised Tools

For servicing this product Specialised tools are required.
1.2.1 Static Strap:
To be used as ESD protection when replacing or handling electronic components.
1.2.2 Down Load Pen Connection: P/N 425930C.
To be used to retrieve data from the electronic controller along with the diagnostic
program on your laptop.
1.2.3 Down Load Serial Connection: P/N 425376C.
To be used to retrieve and download data from the electronic controller along with
the diagnostic program on your laptop.
1.2.4 Perspex Test Lid: P/N 525826.
To be used on the drawer while extended to observe water fill,
wash and drain operations.
1.2.5 Air Gauge and Plumbing. P/N 525819.
To be used to measure the air pressure in the lid seal and plumbing.