Page 4
ELECTRONIC MODULAR FLAKER MODEL MF 36
ice making capacity
AIR COOLED MODELS
K g .
2 0 0
1 8 0
1 6 0
1 4 0
1 2 0
32
27
21
WATER TEMPERATURE
NOTE. The daily ice-making capacity is directly related to the condenser air inlet temperature, water
temperature and age of the machine.
To keep your SCOTSMAN FLAKER at peak performance levels, periodic maintenance checks
must be carried out as indicated on maintenance section of this manual.
SPECIFICATIONS
°C
o
10
21
32
38
o
°C
15
10
Important operating requirements:
• Air temperature
10°C (50°F)
• Water temperature
5°C (40°F)
• Water pressure
1 bar (14 psi)
• Electr. voltage
•
variations from voltage
•
rating specified
•
on nameplate
WATER COOLED MODELS
K g .
1 9 0
1 8 0
1 7 0
1 6 0
1 5 0
32
27
WATER TEMPERATURE
MIN
MAX
40°C (100°F)
35°C (90°F)
5 bars (70 psi)
-10%
+10%
o
°C
21
15
10