Maintenance; Checking The Oil Level (Daily); Drain The Tank (Daily); Clean The Air Filter (Monthly) - Clarke 2242117 Operation & Maintenance Instructions Manual

50l air compressor
Table of Contents

Advertisement

MAINTENANCE

CHECKING THE OIL LEVEL (DAILY)

1. Make sure that the oil level is half
way up the oil sight glass.
2. If not, remove the oil breather cap
and add oil to the reservoir.
• Only use SAE30 compressor oil,
available from your local
CLARKE dealer.

DRAIN THE TANK (DAILY)

After use, always open the drain valve to make sure that any condensate is
drained off "Draining the tank" on page 12.

CLEAN THE AIR FILTER (MONTHLY)

The air filter must be examined monthly, more often in dusty conditions,
1. Remove the filter cover from the
filter.
2. Remove the sponge filter.
3. Use a soft brush to clean the
sponge and the filter cover.
• Clean the filter in warm soapy
water if necessary.
• Rinse and let the filter dry
completely before refitting.
4. Make sure that the filter and filter cover are replaced into position.
• If the filter is damaged you must replace it.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com