MAINTENANCE

CHECKING THE OIL LEVEL (DAILY)

Make sure that there is sufficient oil in the oil reservoir (between the min and
max marks on the dipstick, See page 6) and top-up if necessary.
• Only use SAE40 compressor oil, available from your Clarke dealer.

DRAIN THE TANK (DAILY)

When you have finished using the compressor for the day, always open the
drain valve to ensure that any condensate is drained off.

CLEANING THE AIR INTAKE FILTER (MONTHLY)

The air intake filter should be inspected on a monthly basis, and more often in
dusty conditions,
1. Remove the securing screw from
the air filter cover.
2. Remove the air filter cover from
the compressor.
3. Remove the filter element from
the filter cover.
4. Clean the filter element and the
filter cover using a soft brush.
• If necessary, the sponge filter
may be gently washed in warm
soapy water.
• Rinse and allow the filter to dry
thoroughly before refitting.
5. Ensure that the filter element and filter cover are replaced in their original
position.
• If the filter is damaged, you should obtain a replacement.
6. Replace the securing screw.