2.
Remove the USB board bracket (3).
3.
Release the ZIF connector (1) to which the USB board FFC cable is connected, and then disconnect
the USB board FFC cable from the system board.
4.
Disconnect the USB board cable (2) from the system board.
5.
Release the USB board cable from the routing clips (3) and channel built into the keyboard/top cover.
6.
Remove the two Phillips M2.0×3.8 screws (4) and the Phillips M2.0×4.8 screw (5) that secure the USB
board to the keyboard/top cover.