Carrier 58SC0B Operating Instructions Manual page 33

80% afue, single stage, multi-speed ecm, 4-way multipoise, non–condensing gas furnace
Table of Contents

Advertisement

58SC0B/58SC1B: Installation, Start–Up, Operating and Service and Maintenance Instructions
Low NOx models in the downflow or horizontal positions must use
Table 17
(21,000 BTUh/Burner). See input listed on rating plate.
a. Obtain average yearly gas heat value (at installed altitude) from
local gas supplier.
b. Obtain average yearly gas specific gravity from local gas
supplier.
c. Find installation altitude in
d. Find closest natural gas heat value and specific gravity in
Table 16
or
Table
17.
e. Follow heat value and specific gravity lines to point of
intersection to find orifice size and manifold pressure settings for
proper operation.
f. Check and verify burner orifice size in furnace. NEVER
ASSUME ORIFICE SIZE. ALWAYS CHECK AND VERIFY.
NOTE: If orifice hole appears damaged or it is suspected to have been
redrilled, check orifice hole with a numbered drill bit of correct size.
Never redrill an orifice. A burr-free and squarely aligned orifice hole is
essential for proper flame characteristics.
g. Replace orifice with correct size if required by
Table
16,
Table 17
and
Table
orifices. See EXAMPLE 1.
EXAMPLE 1: (0 to 2000 ft. (0 to 610 M) altitude)
For 22,000 BTUh per burner application use
Heating value = 1000 BTUh/cu ft.
Specific gravity = 0.62
Therefore: Orifice No. 43*
Manifold pressure: 3.7-In. W.C.
*Furnace is shipped with No. 43 orifices.
In this example all main burner orifices are the correct
size and do not need to be changed to obtain proper input rate.
3. Adjust manifold pressure to obtain correct input rate.
a. Turn gas valve ON/OFF switch to OFF.
b. Remove manifold pressure tap plug from gas valve (see
c. Connect a water column manometer or similar device to
manifold pressure tap.
d. Turn gas valve ON/OFF switch to ON.
e. Manually close blower door switch.
f. Set thermostat to call for heat.
g. Remove regulator seal cap and turn regulator adjusting screw
counterclockwise (out) to decrease input rate of clockwise (in) to
increase input rate.
NOTE: DO NOT set manifold pressure less than 3.2-in. w.c. or more
than 3.8-in. w.c. for natural gas at sea level. If manifold pressure is
outside this range, change main burner orifices. Refer to
Table
16,
Table 17
and
Table
15.
h. Install regulator seal cap.
i. Leave manometer or similar device connected and proceed to
Step 4.
4. Verify natural gas input rate by clocking meter.
NOTE: Gas valve regulator adjustment cap must be in place for proper
input to be clocked.
a. Turn off all other gas appliances and pilots served by the meter.
b. Run furnace for 3 minutes in heating operation.
c. Measure time (in sec) for gas meter to complete 1 revolution and
note reading. The 2 or 5 cubic feet dial provides a more accurate
measurement of gas flow.
d. Refer to
Table 16
for cubic ft. of gas per hr.
e. Multiply gas rate (cu ft./hr) by heating value (BTUh/cu ft.) to
obtain input.
f. If clocked rate does not match required input from Step 1,
increase manifold pressure to increase input or decrease manifold
pressure to decrease input. Repeat steps b through e until correct
input is achieved. Reinstall regulator seal cap on gas valve.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Table 16
or
Table
17.
Table
14,
15. Use only factory-supplied
Table
16.
Fig.
Table
Table 15 – Gas Rate (Cu Ft./Hr.)
SIZE OF TEST
SECONDS
FOR 1
1 Cu
REVOLUTION
Ft.
10
360
11
327
12
300
13
277
14
257
15
240
16
225
17
212
18
200
19
189
20
180
21
171
22
164
23
157
24
150
25
144
26
138
27
133
28
129
29
124
30
120
31
116
32
113
33
109
34
106
35
103
21).
36
100
37
97
38
95
39
92
40
90
41
88
42
86
43
84
44
82
45
80
46
78
14,
47
76
48
75
49
73
33
SECONDS
DIAL
FOR 1
2 Cu
5 Cu
1 Cu
REVOLUTION
Ft.
Ft.
Ft.
720 1800
50
72
655 1636
51
71
600 1500
52
69
555 1385
53
68
514 1286
54
67
480 1200
55
65
450 1125
56
64
424 1059
57
63
400 1000
58
62
379
947
59
61
360
900
60
60
343
857
62
58
327
818
64
56
313
783
66
54
300
750
68
53
288
720
70
51
277
692
72
50
267
667
74
48
257
643
76
47
248
621
78
46
240
600
80
45
232
581
82
44
225
563
84
43
218
545
86
42
212
529
88
41
206
514
90
40
200
500
92
39
195
486
94
38
189
474
96
38
185
462
98
37
180
450
100
36
176
439
102
35
172
429
104
35
167
419
106
34
164
409
108
33
160
400
110
33
157
391
112
32
153
383
116
31
150
375
120
30
147
367
SIZE OF TEST
DIAL
2 Cu
5 Cu
Ft.
Ft.
144
360
141
355
138
346
136
340
133
333
131
327
129
321
126
316
124
310
122
305
120
300
116
290
112
281
109
273
106
265
103
257
100
250
97
243
95
237
92
231
90
225
88
220
86
214
84
209
82
205
80
200
78
196
76
192
75
188
74
184
72
180
71
178
69
173
68
170
67
167
65
164
64
161
62
155
60
150