4-way multipoise, non-condensing 33-1/3 in. gas furnace

Advertisement

Quick Links

58SP0A/58SP1A
4-Way Multipoise, Non-Condensing
33-1/3 in. Gas Furnace
Input Capacities: 045K thru 110K BTUh
THE 58SP0A/58SP1A GAS FURNACE
The 58SP0A/58SP1A 4-way Multipoise Gas Furnaces feature Carrier's
QuieTech™ noise reduction system for quiet induced draft operation.
Applications
are
easy
through-the-furnace downflow venting, 13 different venting options, and
easy service access. An inner blower door is provided for tighter sealing
in sensitive applications. The 58SP0A/58SP1A furnaces are factory
shipped for use with natural gas and convertible to propane with
approved accessory kit. The 58SP1A - Low NOx units are designed for
California installations and meet 40 ng/J NOx emission limits. Can be
installed in air quality management districts with a 40 ng/J NOx
emissions limit.
Product Data
with
4-way
multipoise
TM
PERFORMANCE
• Single-stage gas valve
• Variable-speed, Constant Torque (VCT) ECM blower motor
• QuieTech™ noise reduction system with fully insulated cabinet
• Microprocessor based control center
Enhanced diagnostics with LED and reflective sight glass.
Stores fault codes during power outages.
• Adjustable heating air temperature rise
• Adjustable cooling airflow
• Power Heat™ Igniter
• Draft safeguard switch to ensure proper furnace
venting
• Inner blower door for tighter sealing
INSTALLATION FLEXIBILITY
• 4-way Multipoise furnace, 13 vent applications
• HYBRID HEAT® Dual Fuel System compatible
A190080
• All models are chimney friendly when used with
accessory vent kit
APPLICATIONS
design,
• Compact design - only 33-1/3 in. (847 mm) tall
• Propane convertible with gas conversion accessory
• Convenient Air Purifier and Humidifier connections
CERTIFICATON
• Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air
leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with
ASHRAE standard 193
• Residential installations eligible for consumer financing through the
Retail Credit Program
A200315

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 58SP0A

  • Page 1 • HYBRID HEAT® Dual Fuel System compatible A190080 THE 58SP0A/58SP1A GAS FURNACE • All models are chimney friendly when used with accessory vent kit The 58SP0A/58SP1A 4-way Multipoise Gas Furnaces feature Carrier’s APPLICATIONS QuieTech™ noise reduction system for quiet induced draft operation. Applications easy...
  • Page 2: Specifications

    58SP0A/58SP1A: Product Data SPECIFICATIONS Unit Size 045V14-12 045V17-16 070V17-16 070V21-20 090V21-20 090V24-20 110V24-22 RATINGS AND PERFORMANCE All Standard 44,000 44,000 66,000 66,000 88,000 88,000 110,000 All Low NOx Upflow Input Btuh Nonweatherized ICS All Low Nox 42,000 42,000 63,000 63,000...
  • Page 3: Model Number Nomenclature

    58SP0A/58SP1A: Product Data MODEL NUMBER NOMENCLATURE 1, 2 Major 7, 8, 9 11, 12 Voltage 15, 16 Gas Furnace Heating Stages Tier Min. AFUE/NOx Series Heating Input Motor Type Width (1-phase) Minor Series Airflow 08 = 800 CFM 10 = 1000 CFM 12 =1200 CFM C = Comm.
  • Page 4 HEAT RECOVERY VENTILATOR Model HRV ENERGY RECOVERY VENTILATOR Model ERV UV LIGHTS Model UVL Carrier has a wide variety of thermostats for your system, please visit www.Carrier.com to see all thermostat and IAQ products. DESCRIPTION ACCESSORY 14” 17” 21” 24”...
  • Page 5: Typical Wiring Schematic

    58SP0A/58SP1A: Product Data TYPICAL WIRING SCHEMATIC FIELD 24-V WIRING FIELD 115-, 208/230-, 460-V WIRING FACTORY 24-V WIRING FACTORY 115-V WIRING NOTE 2 THERMOSTAT FIVE WIRE FIELD-SUPPLIED TERMINALS DISCONNECT THREE-WIRE HEATING-ONLY 208/230- OR BLOWER DOOR SWITCH 460-V THREE PHASE 208/230-V SINGLE...
  • Page 6 58SP0A/58SP1A: Product Data Air Delivery - CFM (With Filter)* (Continued) COOLING AND HEATING AIR DELIVERY - CFM (Bottom Return with Filter) (SW1-5 and SW2-2 set to OFF, except as indicated. See Notes 1 and 2.) Unit Size: 045V17-16 Clg/CF Switch settings...
  • Page 7 58SP0A/58SP1A: Product Data Air Delivery - CFM (With Filter)* (Continued) COOLING AND HEATING AIR DELIVERY - CFM (Bottom Return with Filter) (SW1-5 and SW2-2 set to OFF, except as indicated. See Notes 1 and 2.) Unit Size: 070V21-20 Clg/CF Switch settings...
  • Page 8 58SP0A/58SP1A: Product Data Air Delivery - CFM (With Filter)* (Continued) COOLING AND HEATING AIR DELIVERY - CFM (Bottom Return with Filter) (SW1-5 and SW2-2 set to OFF, except as indicated. See Notes 1 and 2.) Unit Size: 090V24-20 Clg/CF Switch settings...
  • Page 9 58SP0A/58SP1A: Product Data 1. Nominal 350 CFM/ton cooling airflow is delivered with SW1-5 and SW2-2 set to OFF. Set both SW1-5 and SW2-2 to ON for +7% airflow (nominal 370 CFM/ton). Set SW1-5 to ON and SW2-2 to OFF for +15% airflow (nominal 400 CFM/ton).
  • Page 10 58SP0A/58SP1A: Product Data SEE NOTES: 1,2,4,5,7,8,9 A02066 HORIZONTAL LEFT SEE NOTES: 1,2,3,4,7,8,9 A02063 DOWNFLOW SEE NOTES: 1,2,3,4,7,8,9 A02059 UPFLOW SEE NOTES: 1,2,4,5,6,7,8,9 A02062 DOWNFLOW VENTING NOTES 1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC), ANSI Z223.1/NFPA 54.
  • Page 11 58SP0A/58SP1A: Product Data DIMENSIONS A190084 ACCESSORY VENT SHIP WT. FILTER TOP AND FURNACE SIZE CABINET OUTLET BOTTOM CONNECTION BOTTOM FLUE LB (KG) MEDIA WIDTH WIDTH INLET WIDTH SIZE CABINET SIZE COLLAR 045V14-12 14-3/16 (306) 12-9/16 (237) 9-5/16 (237) 12-11/19 (322) 4 (102) 112 (50.8)
  • Page 12: Guide Specifications

    Draft Safeguard Switch Draft Safeguard Switch (blocked vent safeguard) shall be factory installed to reduce the possibility of vent gas infiltration due to a blocked or restricted vent pipe. © 2020 Carrier. All rights reserved. Edition Date: 07/20 Catalog No: 58SP0A-02PD Replaces:58SP0A-01PD...

This manual is also suitable for:

58sp1a

Table of Contents