Carrier 58SC0B Operating Instructions Manual page 29

80% afue, single stage, multi-speed ecm, 4-way multipoise, non–condensing gas furnace
Table of Contents

Advertisement

58SC0B/58SC1B: Installation, Start–Up, Operating and Service and Maintenance Instructions
Display
FLt
Ht
Cooling and Heat Pump blower
CL
Cfn
HoD
Cod
dir
tnn
inF
Ct
rSt
The Main Menu provides access to operating parameters of the furnace
control including airflows as well as other diagnostics. See
the location of the pushbuttons. Scroll through Main Menu by pressing
MENU/SELECT button. Press NEXT/OPTION to display the current
setting of the parameter (value will flash). Additional presses will scroll
through setting options. Press MENU/SELECT button to save a new
setting and return to the Main Menu. The display will flash three times to
confirm a new setting selection has been saved.
of the menu and settings.
Table 12
parameter adjustment and applicability.
NFC and Supported App Method
This furnace control board is also equipped with NFC (Near Field
Communication) technology which allows the adjustment of operating
parameters, diagnostics, and service via a field-supplied mobile device
with NFC capability and supported mobile app. Remove 115-V power
from the furnace control board to use this method. See
location of the NFC antenna. Additional instructions and help may be
available through the supported mobile app.
Scan the mobile app QR Code on page 1 of this manual for more
information and a link to download the mobile app.
Control Board Replacement
If the control board must be replaced, the new board must be
programmed with the correct Model Program Number before the furnace
will operate. Do NOT program the control board with a Model Program
Number different than what is specified on the rating plate. The control
may be programmed by either of these approved methods:
1. Use the supported mobile app to flash the model program onto the
board using Near Field Communication (NFC). Scan the QR code
on page 1 of this manual for more information and a link to
download the mobile app.
2. Use the correct Super Plug (available from distributor / replacement
component) for the control board to copy the correct model
program onto the new board.
Further details and instructions for these programming methods are
provided with the replacement control board.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Table 12 – Main Menu Options
Operating Mode
Use
Faults code menu stores the 7 latest faults in memory. If no faults, None (
Last 7 faults that occurred
displayed. To clear fault history, scroll to Clear (
Fig. 45
Heating Airflow Setting. Adjust higher to lower Temp. Rise; lower to increase Temp. Rise.
Heating blower speed
See Start-Up Procedures. See
Cooling Airflow Setting. See
speed
Refer to cooling or heat pump equipment data for required airflow settings.
Constant Fan Airflow Setting. See
Constant Fan blower speed
airflows.
Value shown in seconds. Shorter delays may leave unused heat in ducts. Longer delays
Heat OFF Delay
may blow cold air at the end of heating demands.
Value shown in seconds. Shorter delays may leave unused energy in furnace coil.
Cool OFF Delay
Longer delays may re-evaporate condensate.
Direction
Adjusts display orientation 180 degrees between up flow (
Primary (
Twinning
twinned furnace system. Use of accessory kit required. See kit instructions.
Do NOT program the control board with a Model Program Number different than what is
specified on the rating plate. Alternates displaying the saved Model Program Number
Program # and Software
(
Use to validate components are functioning as intended. See Component Self-Test
Component Test
instructions in the Start-Up Procedures section.
Reset
Reset settings to Factory Default by selecting Yes (
Fig. 28
Fig. 44
shows the flow
provides additional information on
Fig. 28
or Furnace Service Label for codes.
Fig. 44
Fig. 44
) or Secondary (
Pri
SEC
) and Software Version (
pRG
uEr
for
FURNACE OVERHEATING HAZARD
Failure to follow this caution could result in reduced furnace life.
Do NOT program the control board with a Model Program Number
different than what is specified on the rating plate. Parameter options
will not match design values.
for the
29
) and press MENU/SELECT. See
Clr
for allowable selections and
for allowable selections and
Table 9
Fig. 44
for allowable selections and
) and down flow (
UPF
) furnace selection. Adjust only if furnace is used in a
).
).
YEs
CAUTION
!
) will be
non
Table 9
for airflows.
for airflows.
Table 9
for
).
dnF