Triggers And Alarms; Alarm Inputs - Bosch 480 Series Installation And Operation Manual

Hide thumbs Also See for 480 Series:
Table of Contents

Advertisement

48
en | Operating instructions
5.11

Triggers and alarms

Various types of events change the way the unit works. These events are:
The way the unit reacts to events depends on how it is programmed.
An event can cause either a trigger or an alarm. A trigger changes the way the unit works but
does not require a response from the user. An alarm also changes the way the unit works but,
in addition, usually activates several indicators and requires the user to acknowledge the
alarm situation.
The unit reacts to an event in any one of the following ways:
Alarms
Triggers
Background events
Triggers and alarms can change background tasks that a user may not notice. Unit responses
that are not visible to the user are, for example, a change in recording speed, the activation of
the output relay, and event logging. The unit can also be configured to record upon the
activation of an alarm input. A trigger may change the way the camera images are displayed on
the monitors without requiring intervention.
5.11.1

Alarm inputs

If an input causes an alarm
AM18-Q0605 | v2.0 | 2012.04
an alarm input signal applied to the unit
motion detection in a camera signal
a loss of video from one of the cameras
an internal alert from the unit itself (i.e. disk failure, temperature alarm)
A beeper sounds.
A status message is displayed.
An alarm icon is displayed.
The border around a cameo changes color to red.
An alarm
or video loss
An output relay is activated.
A motion
indicator flashes.
The view modes on the monitors change.
A controllable camera might be moved to a pre-defined position.
Recording behavior changes.
The unit changes the way it operates via pre-defined profiles.
Monitors A and B can switch to a pre-programmed view mode.
Monitor A: The border around the displayed cameos is red. The alarm icon is displayed in
the corresponding cameo. An alarm status message is displayed.
Monitor B: Full screen or sequenced display of pre-programmed cameras.
The alarm beeper sounds. The alarm
A controllable camera might be moved to a pre-defined position.
Installation and Operation manual
Digital Video Recorder 440/480 Series
indicator flashes.
indicators flash.
Bosch Security Systems

Advertisement

Table of Contents
loading

This manual is also suitable for:

440 seriesDvr 440Dvr 480Dvr-480-08a050Dvr-480-08a000

Table of Contents