24
en | Hardware setup
4.5

Ethernet connection

The standard RJ-45 Ethernet socket is used to connect the unit directly to a PC or to a
network. To connect directly to a network hub, use a straight-through network cable. To
connect directly to a PC, use a cross-over network cable. Consult with your local IT personnel
for the specific type of cable needed. The maximum cable length from node to node is limited
to 100 meters (300 feet).
Specifications
Connection: 10/100 BaseT, IEEE 802.3
Differential signal voltage: ± 2.8 V maximum, inputs have transient overvoltage protection
Ethernet port details: EEE 802.3/802.3u — 100Base-TX/10Base-T physical layer
Auto negotiation: 10/100, full/half duplex
Cable length: 100 meters (100 ohm unshielded twisted pair cable or 150 ohm shielded
twisted pair cable, category 5 or higher).
Impedance: built-in compensation for impedance matching
Indicators: ACT, 10/100
Figure 4.6 RJ-45 Ethernet connector
Signal name
LAN_TX +
LAN_TX -
LAN_RX +
N/C
N/C
LAN_RX -
N/C
N/C
Table 4.2 LAN - RJ-45 Ethernet socket
AM18-Q0605 | v2.0 | 2012.04
Pin number
1
2
3
4
5
6
7
8
Installation and Operation manual
Digital Video Recorder 440/480 Series
Description
Ethernet transmit line plus
Ethernet transmit line minus
Ethernet receive line plus
No connection
No connection
Ethernet receive line minus
No connection
No connection