Work Area Safety

Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Line Voltage
0 to 50KV
50 to 200KV
200 to 350KV
350 to 500KV
500 to 750KV
750 to 1000KV
Allow for platform movement, electrical line sway
or sag, and beware of strong or gusty winds.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Part No. T107028_78
Obey all local and
governmental
regulations regarding
required clearance from
electrical power lines. At
a minimum, the required
clearance contained in
the chart below must be
followed.
Required Clearance
3.05 m
4.60 m
6.10 m
7.62 m
10.67 m
13.72 m
Keep away from the
machine if it contacts
energized power lines.
Personnel on the ground
or in the platform must
not touch or operate the
machine until energized
power lines are shut off.
GS-30 • GS-32 • GS-46 • GS-47
Work Area Safety
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity or the
maximum platform capacity of the platform
extension.
Maximum capacity
Platform
Platform
Model
retracted
GS-1530
272 kg
159 kg
GS-1532
272 kg
159 kg
227 kg
113 kg
GS-1930
227 kg
113 kg
GS-1932
GS-2032
363 kg
249 kg
GS-2632
227 kg
113 kg
227 kg
113 kg
GS-3232
544 kg
431 kg
GS-2046
GS-2646
454 kg
340 kg
318 kg
204 kg
GS-3246
GS-4047
350 kg
237 kg
Platform retracted
Extension only
Operator's Manual
Platform extended
Extension
Maximum
only
only
occupants
113 kg
113 kg
113 kg
113 kg
113 kg
113 kg
113 kg
113 kg
113 kg
113 kg
113 kg
Platform extended
Platform only
2
2
2
2
2
2
2
2
2
2
2
9