6.2. Specifications

Item
General
Dimensions (W x L x H) in mm
Weight
Housing materials
Maximum number of modules
Maximum number of digital inputs
Maximum number of digital outputs
Maximum number of IO-Link ports
Electrical
Internal current consumption
at 24 V DC (Via US1)
Protection against polarity reversal
Loop through current between power
connector XD1 to XD2
Operating voltage
US1
Under-voltage detection
Max. current
Operating voltage
US2
Max. current
Voltage drop to valve supply
Galvanic isolation
Solenoid valve
JSY series
Applicable series
SY series
VQC series
Max. number of solenoid valves
Load
Output type of solenoid
Over current protection
Over current detection
NOTE
Maximum permissible current of 7/8 inch 5 pins plug connector is 10A.
So for example, the EX245-SPN3A can use 4A and a loop through current of 6A can be drawn
between connectors "XD1" and "XD2"
Table. 6-1 Specifications
EX245-SPN1A
EX245-SPN2A
85 x 127.5 x 89.5
465 g
64 (independent of solenoid valves)
300 mA or less
Yes (US1 and US2)
16 A or less
24 VDC +20%/-15%
Detected: < approx. 19.2 VDC
24 VDC +20%/-15%
Max. 1.2 V at 24 VDC
Yes (between US1 and US2)
JSY3000, JSY5000
SY3000, SY5000
VQC2000, VQC4000
32 solenoid coils
Solenoid valve with surge voltage suppressor of 24 VDC,
1 W or less (SMC)
Source / PNP (negative common)
- 37 -
Description
EX245-SPN3A
85 x 147.7 x 89.5
PBT
8
128
32
200 mA or less
6 A or less
6 A total
4 A
Yes
Yes
No.EX※※-OMW0011-B
540 g