Hoshizaki KM-1300SWH-E Service Manual page 26

Table of Contents

Advertisement

PROBLEM
[4] Water
a) Water Solenoid
continues to
Valve
be supplied in b) Controller Board
freeze cycle.
[5] No water
a) Water Supply Line
comes from
Spray Tubes.
Water Pump
b) Water Solenoid
will not start, or
Valve
freeze cycle
time is too
c) Water System
short.
d) Pump Motor
e) Controller Board
[6] Fan Motor will a) Fan Motor
not start, or is
not operating.
b) Controller Board
[7] All components a) Refrigerant
run but no ice
is produced.
b) Compressor
c) Hot Gas Solenoid
Valve
d) Line Valve
e) Water Solenoid
Valve
f) Water Supply Line
[Water-cooled model
only]
POSSIBLE CAUSE
1. Diaphragm does not close.
1. Defective.
1. Water pressure too low and 1. Check and get
water level in Water Tank
too low.
1. Dirty mesh filter or orifice
and water level in Water
Tank too low.
1. Water leaks.
2. Clogged.
3. Pump out Check Valve
leaking by.
1. Motor winding opened.
2. Bearing worn out.
3. Wiring to Pump Motor.
4. Defective Capacitor.
5. Defective or bound impeller. 5. Replace and clean.
6. Mechanical Seal worn out.
1. Defective.
1. Motor winding opened.
2. Bearing worn out.
3. Wiring to Fan Motor.
4. Defective Capacitor.
5. Fan blade bound.
1. Defective.
1. Undercharged.
2. Air or moisture trapped.
1. Defective valve.
1. Continues to open in freeze 1. Check and replace.
cycle.
1. Continues to close in
freeze cycle.
1. Water Solenoid Valve is
wide open during freeze.
1. Condenser water pressure
too low or off and Pressure
Control opens and closes
frequently.
26
REMEDY
1. Check for water leaks
with icemaker off.
1. See "II.2.[e] CHECKING
CONTROLLER BOARD."
recommended pressure.
1. Clean.
1. Check connections for
water leaks, and replace.
2. Clean.
3. Check assembly; clean.
1. Replace.
2. Replace.
3. Check for loose
connection or open, and
replace.
4. Replace.
6. Check and replace.
1. See "II.2. [e] CHECKING
CONTROLLER BOARD."
1. Replace.
2. Replace.
3. Check for loose
connection or open, and
replace.
4. Replace
5. Check and replace.
1. See "II.2. [e] CHECKING
CONTROLLER BOARD."
1. Check for leaks and
recharge.
2. Replace Drier, and
recharge.
1. Replace.
1. Check and replace
1. Check for water leaks
with icemaker off.
1. Check and get
recommended pressure.

Advertisement

Table of Contents
loading

Table of Contents