Configuring the Terminal
Before the terminal program can communicate with the camera,
the transmission parameters must be matched. Make the
following settings for the terminal program:
19,200 bps
8 data bits
No parity check
1 stop bit
No protocol
Command Inputs
After the connection has been established, you must log on to
the camera to access the main menu. Other submenus and
functions can be accessed using the on-screen commands.
1.
If necessary, turn off the local echo so that entered values
are not repeated on the display.
2.
Enter one command at a time.
3.
When you have entered a value, such as the IP address,
check the characters you have entered before pressing
Enter to transfer the values to the camera.
Assigning an IP Address
Before you can operate a camera in your network you must first
assign it an IP address that is valid for your network.
The following default address is preset at the factory:
192.168.0.1
1.
Start a terminal program such as HyperTerminal.
2.
Enter the user name service. The terminal program
displays the main menu.
3.
Enter command 1 to open the IP menu.
4.
Enter 1 again. The terminal program displays the current IP
address and prompts you to enter a new IP address.
5.
Enter the desired IP address and press Enter. The terminal
program displays the new IP address.
6.
Use the displayed commands for any additional settings
you require.