Appendix 1 Instructions For Compliance With The Eu Directives - Mitsubishi Electric FR-A802-P Instruction Manual

Separated converter type for parallel operation
Table of Contents

Advertisement

Appendix 1
The EU Directives are issued to standardize different national regulations of the EU Member States and to facilitate free
movement of the equipment, whose safety is ensured, in the EU territory.
Since 1996, compliance with the EMC Directive that is one of the EU Directives has been legally required. Since 1997,
compliance with the Low Voltage Directive, another EU Directive, has been also legally required. When a manufacturer
confirms its equipment to be compliant with the EMC Directive and the Low Voltage Directive, the manufacturer must declare
the conformity and affix the CE marking.
• The authorized representative in the EU
The authorized representative in the EU is shown below.
Company name: Mitsubishi Electric Europe B.V.
Address: Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany
EMC Directive
We declare that this inverter conforms with the EMC Directive and affix the CE marking on the inverter.
• EMC Directive 2014/30/EU
• Standard(s): EN 61800-3:2004+A1:2012 (Second environment / PDS Category "C3")
• Please ensure you chose the right inverter for the intended environment. When using the inverter in a residential area, take
appropriate measures and ensure the conformity of the inverter used in the residential area.
• The installer shall provide a guide for installation and use, including recommended mitigation devices.
Note:
First environment
Environment including buildings/facilities which are directly connected to a low voltage main supply which also supplies
residential buildings. Directly connected means that there is no intermediate transformer between these buildings.
Second environment
Environment including all buildings/facilities which are not directly connected to a low voltage main supply which also supplies
residential buildings.
 Note
Ensure the EMC filter is enabled, install the product as stated below, and then carry out any wiring.
• The FR-CC2-P converter unit used with this inverter is equipped with a built-in EMC filter (Class C3). Enable the EMC
filter. (For details, refer to
• Connect the inverter and the converter unit to an earthed (grounded) power supply.
• Install the motor and controller cable found in the EMC Installation Manual (BCN-A21041-204) and Technical News
(MFS-138) according to the instructions.
• To make full use of the built-in EMC filter, motor cable lengths should not exceed 20 m.
• Ensure that the finalized system which includes an inverter and converter unit complies with the EMC Directive.