42- Security And Arming - QOLSYS IQ4 Hub Installation Manual

All-in-one 7” (17.8cm) touchscreen
Table of Contents

Advertisement

PROGRAMMING
SECURITY AND ARMING
Security and Arming
Change arming settings, entry and exit delays, enable Duress Authentication
and more.
Setting
Default
Dealer Code*
Installer Code
Swinger Shutdown
Enabled
Swinger Shutdown
Count
Panel Tamper
Enabled
2222
Code to access all options
1111
Code to access installer options only
Determines whether the panel allows the same sensor to trip the
alarm more than once during the same arming period. When Enabled,
the sensor will trip according the to the Swinger Shutdown Count
setting. When Disabled, a sensor may trip up to 128 times per arming
period.
Determines the number of times the same sensor is allowed to trip the
alarm during the same arming period (1-6). Swinger Shutdown must
1
be enabled in order for this setting to work.
to 3
This setting enables or disables the Panel Tamper switch on the back of
the panel.
NOTE: for UL/cUL and EN Grade 2 this setting shall be Enabled