PROGRAMMING
SIREN AND ALARMS
Siren and Alarms
Change siren and alarm settings for certain types of alarm events.
Setting
Panel Sirens
Siren Annunciation
Fire Verification
Default
All Sirens Off: This will disable the siren for all alarm types, except
for life safety devices, including any hardwire or wireless external
sirens.
All Sirens
All Sirens On: This is the default setting which enables the siren
On
for all alarms
Installer/Test Mode: This disables the siren for all alarm types
including any paired or hardwired external sirens for 30 mins then
all sirens are re-enabled
Panel siren pauses periodically to announce which locations have
Disabled
triggered the alarm.
NOTE: for UL/cUL this feature is not allowed for Fire, CO, Burglar Alarm
When enabled, panel requires two fire events from smoke
Disabled
detector (one detector twice or two detectors once each)
NOTE: Not allowed on UL/cUL installations
QOLSYS CONFIDENTIAL AND PROPRIETARY
Description
PAGE
39
OF
197
FIND IT
Swipe down
for access
SETTINGS
ADVANCED SETTINGS
ENTER CODE (1111, 2222)
INSTALLATION
SIREN AND ALARMS