To Insulate The Water Piping - Daikin ERGA04EAV37 Installer's Reference Manual

Hide thumbs Also See for ERGA04EAV37:
Table of Contents

Advertisement

8
|
Piping installation

8.6.8 To insulate the water piping

Installer reference guide
112
a
b
a Drainback connection
b Spillover connection
c Hose with non-return valve (1/2")
With installed drainback solar kit (option)
1 Combine the fill and drain kit (option) with the drainback solar kit (option) to
fill the storage tank.
2 Connect the hose with non-return valve to the fill and drain kit.
Follow the steps described in the previous chapter.
The piping in the complete water circuit MUST be insulated to prevent
condensation during cooling operation and reduction of the heating and cooling
capacity.
b
ERGA04~08EAV3+V3A+V37 + EHSH/X(B)04+08P30+50EF
c
a
Daikin Altherma 3 R ECH₂O
4P678716-1A – 2022.07