Error Code/Symptom
035-XXX-S99
(Failed
RAID test on PCI slot S. S =
number of failing PCI slot.
Check System Error Log
before replacing a FRU.)
035-XXX-SNN
(Check
System Error Log before
replacing a FRU.
S =
number of failing PCI slot;
NN = SCSI ID of failing fixed
disk.)
035-253-S99
(RAID
adapter initialization failure)
075-XXX-000
(Failed
Power Supply test)
089-XXX-001
(Failed
Microprocessor test)
089-XXX-002
(Failed Optional
Microprocessor test)
180-XXX-003
(Failed
System Board LED test)
201-XXX-0NN
(Failed
Memory test, see "Memory
Settings" on page 32.) NN =
DIMM location.
201-XXX-999 (Multiple
DIMM failure, see error text.)
202-XXX-001
(Failed
System Cache test)
202-XXX-002
(Failed
System Cache test)
206-XXX-000
(Failed
Diskette Drive test)
215-XXX-000
(Failed
IDE CD-ROM test)
217-XXX-000
(Failed
BIOS Fixed Disk test)
Note:
If RAID is
configured, the fixed
disk number refers to
the RAID logical
array.
116
Hardware Maintenance Manual: xSeries 220
1.
Adapter
2.
SCSI Backplane
3.
Cable
1.
Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.
1.
ServeRAID Adapter in slot S is not configured properly. Obtain the basic and
extended configuration status and refer to the ServeRAID Hardware Maintenance
Manual for more information.
2.
Cable
3.
Adapter
1.
Power Supply
1.
Microprocessor
1.
Optional Microprocessor 2
1.
System Board
1.
DIMM Location J1-J4
2.
Memory card
1.
See error text for failing DIMMs
1.
Microprocessor CPU 1
1.
Microprocessor CPU 2
1.
Cable
2.
Diskette Drive
3.
System Board
1.
CD-ROM Drive Cables
2.
CD-ROM Drive
3.
System Board
1.
Fixed Disk 1
FRU/Action

Advertisement

Table of Contents
loading

Table of Contents