Diagnostic error codes
Error Code/Symptom
001-XXX-000
(Failed
core tests)
001-XXX-001
(Failed core
tests)
001-250-000
(Failed
System Board ECC)
001-250-001
(Failed
System Board ECC)
005-XXX-000
(Failed
Video test)
011-XXX-000
(Failed
COM1 Serial Port test)
011-XXX-001
(Failed COM2 Serial Port test)
014-XXX-000
(Failed Parallel Port test)
015-XXX-001
(USB interface not found,
board damaged)
015-XXX-015
(Failed USB External
Loopback test)
015-XXX-198
(USB device connected
during USB test)
020-XXX-000
(Failed
PCI Interface test)
030-XXX-000
(Failed
Internal SCSI interface test)
(Failed
030-XXX-00N
SCSI test on PCI slot N.
Check system error log before
replacing a FRU.)
035-XXX-099
Note: In the following error codes, if XXX is 000, 195, or 197do not replace a FRU.
The description for these error codes are:
000
The test passed.
195
The Esc key was pressed to abort the test.
197
This is a warning error and may not indicate a hardware failure.
For all error codes, replace/follow the FRU/Action indicated.
1.
System Board
1.
System Board
1.
System Board
1.
System Board
1.
Video Adapter (if installed)
2.
System Board
1.
System Board
1.
System Board
1.
System Board
1.
System Board
1.
Make sure parallel port is not disabled
2.
Re-run USB External Loopback test
3.
System Board
1.
Remove USB devices from USB1 and USB2
2.
Re-run test
3.
System Board
1.
System Board
1.
System Board
1.
Adapter in Slot N
1.
No adapters were found.
2.
If adapter is installed re-check connection.