Function list

Communication-related function list (Application)
Category
Subcategory
Network
Open network
Common
protocol
Profile
Application
Functional
function
safety
Cyclic
transmission
RAS function
Application
Synchronization
function
Network system
startup
Parameter
setting
Setting change
CC-Link IE TSN
Network
diagnostics
Time
synchronization
1 CC-Link IE TSN
6
1.1 Functions and configuration
Function
Description
CC-Link IE TSN
This servo amplifier supports CC-Link IE TSN.
communication protocol
CC-Link IE TSN
Network configuration settings and station-specific mode selection
communication setting
are performed by using GX Works3.
SLMP
This function supports SLMP (SeamLess Message Protocol).
Parameter setting and monitoring are enabled.
CSP+
File for describing the necessary information for startup, operation,
and maintenance of CC-Link family connected products.
Safety communication
Connecting the servo amplifier with a programmable controller that
function
supports functional safety enables safety sub-functions.
Hold/Clear of output at
When the CPU module of the cyclic master is at STOP, when the stop
CPU STOP and CPU
error occurs, Hold/Clear is automatically set on the refresh device
stop error
output. The servo amplifier stops regardless of the setting of Hold/
Clear of the cyclic master.
Automatic return
When a station that has been disconnected due to a data link error
becomes normal, that particular station will automatically reconnect
to the network, and restart the data link.
CC-Link IE TSN
The control cycle of the slave station can be synchronized via the
network synchronous
CC-Link IE TSN in accordance with the synchronization cycle
communication function
specified by the master station. Thus, operation timing of other slave
stations connected to the same network can be synchronized.
Motion mode (high-
The communication cycle between the master station and the slave
speed)
station can be set to 31.25 μs.
Detect Now function
The master station reads the information (a model code, a device
version, etc.) of the servo amplifier that is connected to the network
and automatically sets the network configuration.
Station mode check
The master station checks whether the master station and the servo
amplifier are in the same station mode by obtaining the station mode
of the servo amplifier.
Parameter automatic
This is a function where the controller automatically writes the servo
setting
parameters when the servo amplifier is returning/entering.
Remote reset
This is a function to reset a servo amplifier via the network. Servo
parameters to be enabled at power cycle are reflected by resetting
the servo amplifier.
IP address setting
IP addresses are delivered from the controller to servo amplifiers via
CC-Link IE TSN.
Reserved station
Stations not connected to the network can be included in the total
specification/
number of stations for future connection.
cancellation
Clock function
This function is used to acquire time information from the grand
master (the station serving as a clock source) via CC-Link IE TSN so
that this information may be used for the time management of
functions performed by the servo amplifier, such as alarm history.
Details
Detailed explanation
Page 7
Communication
specifications
Page 10 Startup
Page 16 CC-Link IE
TSN communication
protocol
MR-J5 User's Manual
(Hardware)
MR-J5 User's Manual
(Function)
Page 15 Hold/Clear
of output at CPU STOP
and at CPU stop error
Page 15 Motion
mode (high-speed)
setting
Page 14 Parameter
automatic setting
Page 15 Remote
reset
Page 13 IP address
setting function
Page 12 CC-Link IE
TSN Network diagnostics
Page 15 Clock
function