5.6

Boiler fixing

E9095
Installation
1
Fig. 7
5
1
13
 Put on the flange 1)(Fig. 7) the screw and two nuts.
 Fix the flange 1)(Fig. 8) to the boiler door 4) using screws 2)
and (if necessary) the nuts 3) interposing the insulating gas-
ket 5).
The seal between burner and boiler must be
airtight.
WARNING
4
2
GB
3
E9094
Fig. 8
2902843