7-2-6

Reader/Writer Setting Commands: Communications Settings

SET TAG COMMUNICATIONS CONDITIONS
 Function
This command sets the communications conditions for the Reader/Writer.
 Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
Reserved/Reserved Area
Cnt Response/Update Counter
Response
CmdData/Command Data
RF communication mode
Communications Speed
RF communication timeout
time
Write Verification
Communications Diagnostics
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Data type
Size
WORD
2 bytes
3001 hex
WORD
2 bytes
0000 hex (Not used.)
WORD
2 bytes
0000 hex (Not used.)
WORD
2 bytes
0000 hex (Not used.)
WORD
2 bytes
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
WORD
2 bytes
Specifies the communications mode.
0000 hex: Once
0001 hex: Auto
0002 hex: Focus
0003 hex: Repeat
Default setting: 0000 hex
WORD
2 bytes
Specifies the communications speed.
0000 hex: Auto
0001 hex: High speed
0002 hex: Normal speed
Default setting: 0000 hex
WORD
2 bytes
Specifies the RF communications timeout
time.
0001 hex to EA60 hex
(1 to 60,000 [msec])
Default setting: 00FA hex (250 msec)
WORD
2 bytes
Specifies whether to perform write verifica-
tion.
0000 hex: Do not verify.
0001 hex: Verify
Default setting: 0001 hex
WORD
2 bytes
Specifies whether to perform communications
diagnostics.
0000 hex: Do not verify.
0001 hex: Verify
Default setting: 0000 hex