Plug And Play (Pnp) Configuration; Rps Configuration - Bosch B450-M Installation Manual

Table of Contents

Advertisement

Conettix Plug-in Communicator
When the cellular communicator senses two or more towers for the seconds set at this
parameter, the control panel records a Single Tower restoral event.
TCP Keepalive Time (sec)
Default: 0
Selections: 0 (disabled) to 1000 (minutes)
Time in minutes between keep-alive messages. Keep alive messages make sure that a
connection stays active.
Only change from default for high security UL1610 commercial listed installations.
5.2

Plug and Play (PnP) configuration

With PnP, the module automatically imports the control panel settings for the module and
applies them to the module.
You can use this feature for the following control panels:
To disable this feature for PnP control panels, disable the Panel Programming Enable
parameter before you connect the module.
Notice!
By default, when you connect a field replacement module to an existing SDI2 or option bus
control panel, the control panel overrides the module settings (PnP). To keep the current
settings for the new module, use USB configuration to disable Panel Programming Enable.
Using PnP
1.
2.
3.
4.
5.
The module imports the settings and then programs the connected module.
5.2.1

RPS configuration

For control panels that support RPS configuration, you can program the control panel to
configure the module with PnP.
For configuration parameters, refer to Configuration parameters, page 17.
You can also refer to the RPS Help.
Use the following sections in RPS:
Bosch Security Systems, Inc.
AMAX 3000/4000 firmware version v1.5 or higher
B9512G/B9512G-E
B8512G/B8512G-E
B6512
B5512/B5512E
B4512/B4512E
B3512/B3512E
D9412GV4/D7412GV4/D7212GV4
Solution 2000/3000 firmware version v2.0 or higher
Program the control panel configuration for the module. Use RPS, or A-Link, or a keypad.
Send the programming to the control panel.
Set the address switch for the control panel (SDI2 control panels use address 1 or 2,
option bus control panels use address 134 or 250).
Connect the module to the control panel bus.
Apply power to the control panel.
SDI2 Modules > IP Communicator
SDI2 Modules > IP Communicator > B450 Cellular* (For D9412GV4/D7412GV4/D7212GV4
v1.xx, use the B420 Ethernet Communicator section.)
Installation Manual
Configuration | en