UDV Series
Igniter, Electrode Testing and
Replacement
Step 1. Remove the outer jacket door.
Step 2. Repeatedly depress the igniter button while
viewing the pilot through the flame viewing
window. If a spark is present, the circuit is
OK. If there is no spark, proceed to step 3.
Step 3. Remove the white wire from the gas
control's igniter wire. Hold the igniter lead
from the gas control to an unpainted
surface such as the feedline and depress
the igniter. If there is a spark, the igniter is
OK. Otherwise, the igniter is not
functioning and the pilot assembly must be
replaced. See service procedure II on
pages 9 & 10.
UDV SERVICE PROCEDURE V

Igniter, Electrode Testing and Replacement

17