Installation ––––––––––––––––––––––––––––––––––––––––––––––––––––––––
CAUTION!
No service or maintenance should be performed until the technician
has thoroughly read this service manual. Except for routine cleaning
and sanitizing, only qualified technicians should attempt to service
or maintain this equipment.

Countertop Installation

Installation instructions for freestanding model may be found on
1 . A clearance of at least 3" (77 mm) is required behind and on
each side of the dispenser for electrical connection and ventilation
(Fig . 1) .
2 . Rough-in the electrical service and water line .
§ Electrical: 115V, single phase, 15A receptacle required . The dispenser
has an integral 8 ft . (2 .4 m) cord and plug .
§ Water: supply line (with shut-off valve) connects to the dispenser's 1/4"
MPT inlet .
NOTICE!
If installing optional Drip Tray Drain Kit or Leg Accessory, complete
those steps before proceeding.
3 . Connect water line . Recommended routing (Fig . 2) allows easy access
to water for cleaning and sanitizing procedure .
4 . Connect power supply .
5 . Sanitize the dispenser prior to use (see
page
13) .
6
Dispenser and Icemaker 7CI100A/7FS100A
page
Cleaning and Sanitizing on
Fig . 1
8 .
countertop models
minimum 3" (77 mm)
clearance required
Fig . 2
3' (76 mm)
1/4" MPT