Control Diagnostics

Troubleshooting
Make the following visual checks before troubleshooting:
1. Check to see that the power to the furnace and the
integrated ignition/blower control board is ON.
2. The manual shutoff valves in the gas line to the furnace
must be open.
3. Make sure all wiring connections are secure.
4. Review the Sequence of Operation.
Start the system by setting thermostat above room
temperature. Observe system response. Then use the
information provided in this section to check the system
operation.
The furnace has a built-in, self-diagnostic capability. If a
system problem occurs, a fault code is shown by a red LED
on the control board. The control continuously monitors its
own operation and the operation of the system. If a failure
occurs, the LED will indicate the failure code. The flash
codes are presented in Table 12.
Fault Code History Button
The control stores the last five fault codes in memory. A
pushbutton switch is located on the control. When the
pushbutton switch is pressed and released, the control
flashes the stored fault codes. The most recent fault code
is flashed first; the oldest fault code is flashed last. To clear
the fault code history, press and hold the pushbutton switch
in for more than 5 seconds before releasing.
High Heat State LED
On A95DF2V and 95G2DFV models, a green LED is
provided on the control board to indicate high heat state
(see Table 13).
CFM LED
On A95DF2V and 95G2DFV models equipped with a
variable speed motor, an amber LED is provided on the
control board to display CFM. To determine what CFM the
motor is delivering at any time, count the number of times
the amber LED flashes. Each flash signifies 100 CFM; count
the flashes and multiply by 100 to determine the actual CFM
delivered (for example: 10 flashes x 100 = 1000 CFM).
Page 42 of 58
FAILURE CODES - Red LED
HIGH HEAT STATE - Green LED
Issue 1621
Table 12
Table 13