NOTE: See Table 8 for maximum allowed exhaust pipe
length without insulation in unconditioned space during
winter design temperatures below 32° F (0° C). If required,
exhaust pipe should be insulated with 1/2" (13 mm), Armaflex
or equivalent when run through an unconditioned area. In
extremely cold climate areas with temperature below 20° F
(6.7° C) it is recommended that 3/4" (19 mm) Armaflex or
equivalent be used. Insulation on outside runs of exhaust
pipe should be painted or wrapped to protect insulation
from deterioration in accordance with the insulation
manufacturers recommendation. Exhaust pipe insulation
may not be necessary in some specific applications.
NOTE: During extremely cold temperatures, below
approximately 20° F (6° C), units with long runs of vent
pipe through unconditioned space, even when insulated,
may form ice in the exhaust termination that prevents the
unit from operating properly. Longer run times of at least 5
minutes will alleviate most icing problems. Also, a heating
cable may be installed on exhaust piping and termination
to prevent freeze-ups. Heating cable installation kits are
available, see unit specification sheets for part numbers.
Winter Design Temperatures
ºF (ºC)
32 to 21
(0 to -6)
20 to 1
(-7 to -17)
0 to -20
(-18 to -29)
Refer to 99% Minimum Design Temperature table provided in the current edition of the ASHRAE Fundamentals Handbook.
1
Poly-Propylene vent pipe (PP) by Duravent and Centrotherm
2
NOTE - Concentric terminations are the equivalent of 5' and should be considered when measuring pipe length.
NOTE- Maximum uninsulated vent lengths listed may include the termination (vent pipe exterior to the structure ) and cannot
exceed 5 linear feet or the maximum allowable intake or exhaust vent length listed in table 5 or 6.
NOTE - If insulation is required an unconditioned space, it must be located on the pipe closed to the furnace.
Page 22 of 58
Maximum Allowable Exhaust Vent Pipe Length (in ft.) Without Insulation
In Unconditioned Space For Winter Design Temperatures
1
Vent Pipe
Diameter
2 in.
2-1/2 in.
3 in.
2 in.
2-1/2 in.
3 in.
2 in.
2-1/2 in.
3 in.
Do not use screens or perforated metal in exhaust
terminations. Doing so will cause freeze-ups and may
block the terminations.
For Canadian Installations Only:
In accordance to CSA International B149 installation
codes, the minimum allowed distance between the
combustion air intake inlet and the exhaust outlet of
other appliances shall not be less than 12 inches (305
mm).
Unit Input Size
045
070
PVC
PP
PVC
2
21
18
33
16
N/A
26
12
12
21
11
9
19
7
N/A
14
N/A
N/A
9
6
4
12
N/A
N/A
7
N/A
N/A
N/A
Table 8
Issue 1621
IMPORTANT
IMPORTANT
090
PP
PVC
PP
2
2
30
46
42
N/A
37
N/A
21
30
30
17
28
25
N/A
21
N/A
9
16
16
10
19
16
N/A
13
N/A
N/A
8
8
110
PVC
PP
2
30
30
36
N/A
29
29
27
24
20
N/A
14
14
18
15
12
N/A
7
7
507052-04

Advertisement

Table of Contents
loading

This manual is also suitable for:

Allied air enterprises 95g2dfv

Table of Contents