Table of Contents
Table of Contents
1.1
2.1
Outdoor unit............................................................................... 12
2.1.1
3.1
3.1.1
3.1.2
3.1.3
4.1
4.1.1
4.1.2
4.1.3
4.2
4.2.1
4.3
4.3.1
4.3.2
4.4
4.4.1
4.4.2
4.4.3
4.4.4
4.4.5
4.4.6
4.5
4.5.1
4.5.2
4.6
4.6.1
5.1
5.2
5.3
6.1
8.1
Wiring diagram .......................................................................... 19
8.2
Piping diagram .......................................................................... 20
8.2.1
1
About the documentation
1.1
About this document
INFORMATION
Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.
Target audience
Authorised installers
Installation manual
12
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪ General safety precautions:
12
▪ Safety instructions that you MUST read before installing
▪ Format: Paper (in the box of the outdoor unit)
12
▪ Outdoor unit installation manual:
▪ Installation instructions
▪ Format: Paper (in the box of the outdoor unit)
12
▪ Installer reference guide:
▪ Preparation of the installation, reference data,...
▪ Format: Digital files on
and-manuals/product-information/
Latest revisions of the supplied documentation may be available on
13
the regional Daikin website or via your dealer.
The original documentation is written in English. All other languages
are translations.
Technical engineering data
▪ A subset of the latest technical data is available on the regional
Daikin website (publicly accessible).
▪ The full set of latest technical data is available on the Daikin
extranet (authentication required).
2
About the box
2.1
Outdoor unit
2.1.1
To remove the accessories from the
outdoor unit
1 Lift the outdoor unit.
2 Remove the accessories at the bottom of the package.
18
a
b
1×
1×
18
a
General safety precautions
b
Outdoor unit installation manual
18
c
Fluorinated greenhouse gases label
d
Multilingual fluorinated greenhouse gases label
19
e
Drain plug (located on the bottom of the packing case)
f
Drain cap (1)
g
Drain cap (2)
h
Energy label
3
Preparation
3.1
Preparing the installation site
WARNING
The appliance shall be stored in a room without
continuously operating ignition sources (example: open
flames, an operating gas appliance or an operating electric
heater).
ARXM50~71+RXM42~71N2V1B(9) + RXP50~71M2V1B +
RXA42+50+RXF50+60B2V1B + RXF71A2V1B + RXJ50N2V1B
http://www.daikineurope.com/support-
c
d
e
f
1×
1×
1×
6×
3P512025-6M - 2018.11
g
h
3×
1×
R32 split series