CHAPTER
4

Activate the Detector

Turn-on the detector in a safe area with an atmosphere of 20.9% oxygen and free of hazardous
gas.
1. For first time use, charge the battery for up to 8 hours or until LED light turns green using
the charging adapter provided. Refer to Charge the battery for more information.
2. Press and hold the button for three seconds.
3. For first time use, a Warming sensors message is displayed and a 30 minutes countdown is
displayed. In most cases, this countdown only lasts a couple of minutes.
4. When the detector displays Pump test Block inlet, block the pump inlet with a finger, and
then after a couple of seconds unblock the pump inlet. The detector performs a quick
pump test. A Pump Test passed message is displayed. If you do not block the pump inlet,
the detector will turn off after two minutes. The detector will then perform a self-test,
including testing the sensors. This process could take several minutes. If necessary, you
will be instructed by screen prompts to calibrate newly-installed sensors.
5. When the self-test is complete, press and hold the button to zero sensors. After the
autozero is complete, the detector then checks the sensors for calibration and bump test. If
the detector identifies sensors requiring calibration or bump testing, press the button and
follow the on-screen instructions.

Activate the Backlight

To activate the backlight on the screen, press the button.

Deactivate the Detector

1. Press and hold the button during the powering-off countdown.
2. Release the button when OFF is displayed.
BW Ultra
DETECTOR OPERATIONS
22
User Manual