IBM eServer 260 Series Installation Manual page 56

Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Microprocessor problems
The server emits a continuous
beep during POST, indicating
that the startup (boot)
microprocessor is not working
correctly.
Monitor problems
Testing the monitor
44
IBM xSeries 260 Type 8865: Installation Guide
Action
1. Correct any errors indicated by the light path diagnostics LEDs (see "Light path
diagnostics" on page 50).
2. Make sure that all microprocessors are supported on this server, and that they
all match in speed and cache size.
3. (Trained service technician only) Make sure that the microprocessor 1 is seated
correctly.
4. Reseat the following components:
a. (Trained service technician only) Microprocessor 1
b. Microprocessor VRM 3 or 4
c. Microprocessor tray
5. (Trained service technicians only) If there is no indication of which
microprocessor has failed, isolate the error by testing with one microprocessor
at a time.
6. Replace the following components one at a time, in the order shown, restarting
the server each time.
a. (Trained service technician only) Microprocessor 1
b. Microprocessor VRM 3 or 4
c. (Trained service technician only) Microprocessor tray
7. (Trained service technician only) If there are multiple error codes or light path
diagnostics LEDs that indicate a microprocessor error, reverse the locations of
two microprocessors to determine whether the error is associated with a
microprocessor or with a microprocessor socket. If the error codes or LEDs
indicate an error that is associated with microprocessor socket 3 or 4, reverse
the locations of VRM 3 and VRM 4.
v If the error is associated with a microprocessor, replace the microprocessor.
v If the error is associated with a VRM, replace the VRM.
v If the error is associated with a microprocessor socket, replace the
microprocessor tray.
Action
1. Make sure the monitor cables are firmly connected.
2. Try using a different monitor on the server, or try using the monitor that is being
tested on a different server.
3. Run the diagnostic programs. If the monitor passes the diagnostic programs,
the problem might be a video device driver.
4. Reseat the following components:
a. Remote Supervisor Adapter II SlimLine (if one is present)
b. I/O board
5. Replace the components listed in step 4 one at a time, in the order shown,
restarting the server each time.

Advertisement

Table of Contents
loading

This manual is also suitable for:

8865

Table of Contents