Section 2: Framing

41"
Surrounding construction

Installing The Fireplace

(bottom, sides and top) must
be non-combustible materials,
metal studs, concrete board
The fireplace must be installed in a location that maintains
and concrete, brick, or stone.
clearances to ALL exterior furniture, appliances and other exterior
equipment. Safety, as well as efficiency of operation, must be
considered when selecting the fireplace location. Try to select a
Backframe Min. 38"
both sides Typical
location that does not interfere with foot traffic, has adequate
ventilation, and offers an accessible pathway for ventilated gasses.
41"

Framing (without surround)

Surrounding construction
(bottom, sides and top) must
Frame in the enclosure for the unit with framing materials. The
be non-combustible materials,
metal studs, concrete board
framed opening for the assembled fireplace is 41" wide x 38" high x
and concrete, brick, or stone.
23 ⅞" deep, see Figure 2.
Backframe Min. 38"
NOTE: When constructing the framed opening, please ensure there
both sides Typical
is access to install the gas line when the unit is installed.
Combustible
Combustible
materials
materials
1" clearance
to corners only
36"
36"
38"
38"
1" Clearance to
combustibles to sides
ot Unit
Figure 2. Framing dimensions (without optional surround). Must be back-framed

Clearances

When installing a shelf over the top of the fireplaces, the following
guidelines must be adhered to:
H*38SVO**
36''
36''
24"
Min.
6
38"
12"
40"
41"
41"
23 7/8"
23⅞"
12''
0''
24''
48''
41"
Surrounding construction
(sides and top) must be non-
combustible materials, metal
studs, concrete, brick or stone
Backframe Min. 38"
Both sides typical

Back framing dimensions

Note: ONLY Non-combustible materials must be used in
construction of the enclosure. (top, bottom and sides). Steel studs
in combination with concrete, rock, or stone finishing materials, are
acceptable.
Surrounding construction
(sides and top) must be non-
combustible materials, metal
studs, concrete, brick or stone
Backframe Min. 38"
Figure 2.b Back framing dimensions. (without Optional surround)

Fireplace Facing

When selecting the finish material for your fireplace, it is important
to remember the following: THE LOWER GAS CONTROL PANEL
MUST NOT BE OBSTRUCTED IN ANY WAY - to do so restricts the air
supply for the control compartments and heat exchanger it also
prevents access for servicing controls.
Decorative facing must not extend past the fireplace opening at all,
because it will interfere with the access to retainers for removal of
glass door.
42
39
36
33
30
27
24
21
18
15
12
9
6
3
1
14
13
12
11
10
9
8
7
6
5
4
Mantle width (In.)
Figure 2.c Non-combustible mantles and facings.
WARNING
When covering the upper metal portion of the fireplace with a non-
combustible material, please note the decorative facing materials
may be subject to temperatures in excess of 350F. This should be
considered when selecting facing materials.
Installation
41"
Both sides typical
Non-combustible
header
Non-combustible
facing
Top of fireplace
Top of fireplace opening
3
2
1
XG0817