Section 2: Framing The Fireplace; Clearances - Montigo H34VO Installation & Maintenance Manual

Outdoor residential gas fireplace
Table of Contents

Advertisement

H-Series VO Outdoor Gas Fireplace
Section 2: Framing
Choosing The Fireplace Location
The H-Series VO may be installed in an outdoor setting such as a
patio or balcony. Choose a location that maintains proper clearance to
combustibles as noted in the clearances chart.
Note: The H-Serie VO may not be recessed into the exterior wall.
Figure 2. Choosing the fireplace location.
For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapour barrier. This will
reduce the possibility of a cold-air convection current on the fireplace.
M"
** Optiona l Drain Pan:
M"
available for all models.
H34VO Part No. OD34123
H38VO Part No. OD38123
H42VO Part No. OD42123
** Optiona l Drain Pan:
available for all models.
Figure 2a. Framing dimensions.
H34VO Part No. OD34123
H38VO Part No. OD38123
H42VO Part No. OD42123
H34VO
H38VO
H42VO
** The H-Series VO models have an Optional Stainless Steel Drain
Top View
Pan available. Note, If the Drain Pan is ordered with the fireplace it
must be installed at the time of construction. The Pan cannot be added
at a later date. See Figure 2a above.
C
D
Page 6
C
D
D
Exterior Wall
Insulation material
vapor barrier
(exterior wall).
N"
B
O"
N"
H
O"
Framing Dimensions
M
N
O
P
40⅜" 35⅞" 20¾" 73⅝" 52"
H
G
43⅜" 39⅞" 21"
79
46¾" 44" 22⅝" 85"
A
G
A
D
Top View
F
D
Installation
warning:
When covering the upper metal portion of the fireplace with a non-
combustible material Please Note: The decorative facing materials
may be subject to temperatures in excess of 250° F. This should be
considered when selecting facing materials.
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch.
We recommend careful consideration be given to the effects of elevated
mantel temperatures which may be in excess of product design, for
example: candles, plastic or pictures.
When installing a shelf over the top of the fireplace, the minimum
clearance from the top of the fireplace to a shelf is 9".
When raising the hearth, the minimum clearance from the top of the
M"
fireplace to a combustible ceiling is 36".
** Optiona l Drain Pan:
available for all models.
H34VO Part No. OD34123
H38VO Part No. OD38123
H42VO Part No. OD42123
9"
S
Figure 2b. Framing for shelves over the fireplace.

Clearances

The H-Series VO clearances to combustible materials are listed below
and are the minimum clearances to combustibles that apply to the
following dimensions:
D
C
Q"
Insulation material
vapor barrier
D
(exterior wall).
I
Figure 3. Minimum Corner framing dimensions.
A
Q
Front View
55⅞
60"
If the Optional drain pan is not used during construction; (as shown
in Figure 2a above) ensure any water build-up can escape to the
exterior of the finished enclosure.
Water penetration can occur, and accumulate in the base of the
fireplace, and if not taken into consideration can cause deterioration
of materials, and may cause premature failure of the structure.
G
N"
Clearances
H34VO H38VO
H
Mantel
M
Shelf*
* Dimension plus height of shelf.
G
1" clearance
A
to corners only
Top View
1" clearance
to corners only
D
N"
F
P"
Q"
1" Clearance to
combustibles to sides
N"
ot Unit
E
B
P"
1" Clearance to
combustibles to sides
ot Unit
F
Side View
Important
Insulation material
vapor barrier
(exterior wall).
O"
H42VO
12"
12"
12"
9"
9"
9"
G
J
XG0150 - 081711
Q"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H38voHl38voH42vo

Table of Contents