Section 3: Wiring

Wiring Diagram

Honeywell (Q3450)
Pilot Assembly
Gas Control
Connector
Wall
Switch
Figure 4. Wiring for the H*38SVO*E Honeywell gas control and pilot.

Installing The Remote Switch (H*38SVO*E)

The H*38SVO*E gas valve, located behind the lower trim, may be
connected to a wall switch. The valve generates its own power on a
millivolt circuit. Use only low voltage wire, and DO NOT connect any
external power to it.
Note: The switch location must not exceed 30' from the fireplace.
WARNING
Use Montigo Part No. #RPOVO Water-tight electrical box, or
equivalent equipment. Ensure the box is installed in a dry location
and avoid any moisture. If you install 115V Wire, ensure you use
Ground fault breakers. Also avoid any moisture near or around the
115V Circuit.
8
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Source 110V
Distribution
Panel
White
Water tight
Electrical box
Black

Standing Pilot Diagram

Pilot Adjsutment Screw
Inlet Pressure
Manifold Pressure
Test Connection
Figure 4.b Standing Pilot Diagram (H*38SVO*)
Installation
Power
Generator
Wall Switch
XG0817