7.2.4 If the signal of the SIMCONRST is low or missing
Measure at D601 pin 1~3,2 VDC, if the level is missing or low replace C626, R682, D601.
4/00021-2/FEA 209 544/18 D
If the pulses are correct, replace D601and C693.
If they are incorrect, measure the resistance between D601 pin5 and
D600 pin 74,it should be ~0 ohm.
If the level is ok measure the resistance from the SIMCONRST-pad to ground. It
should be >2 Mohms.
If it is lower, replace C628 and R600.
If the resistance is ok: Measure with the oscilloscope at D601 pin7, give the
board power and start it up. Five pulses with an amplitude of 3,4 V will appear
in the oscilloscope.
If the pulses are correct, replace D601and C693.
If they are incorrect, measure the resistance between D601 pin7 and
D600 pin 73,it should be ~0 ohm.
If the resistance is substantially high, send the unit on
according to the local company directives.
If it is ~0 ohm, replace D600.
If the resistance is substantially high, send the unit on
according to the local company directives.
If it is ~0 ohm, replace D600.
Standard Trouble Shooting Instructions