22 Isolate and correct faults
Copyright © 2003-2007, Nortel Networks
.
then
the application has been activated at the date and time specified
by xx/xx/xx xx:xx.
If the response is
lll:MISP LOOP
APPLICATION
then
the application is not configured for the specified MISP. Configure the
BRIL/BRIT application. Refer to ISDN Basic Rate Interface Feature
Fundamentals (NN43001-580).
If the response is
lll:MISP LOOP
DISABLED
NOT RESPONDING
the application status is not displayed because the MISP running the
application is disabled or faulty and is not responding. Check for
these conditions and refer to the appropriate test procedure.
Enable the MISP as soon as the cause of NOT RESPONDING is
cleared, by typing ENLL lll, where lll is the MISP loop number.
A message indicating that the MISP is enabled and working is
displayed on the console. Observe the red LED on the MISP. If it
extinguishes, the MISP is functioning correctly. If the LED stays lit,
the MISP probably failed the self-test and a message should be
displayed on the maintenance terminal. If the message indicates
that the MISP is faulty, replace it.
If the response is
lll:MISP LOOP
DISABLED
RESPONDING
then
the application status is not displayed because the MISP running the
application is responding but is disabled.Check for these conditions
and refer to the appropriate test procedure.
If the response is
lll:MISP LOOP
APPLICATION
MAN
then
the application is manually disabled using LD 32. Enable the MISP
loop by typing ENLL lll, where lll is the MISP loop number.
A message indicating that the MISP is enabled and working is
displayed on the console. Observe the red LED on the MISP. If it
Nortel Communication Server 1000
ISDN Basic Rate Interface Maintenance
NN43001-718 01.01 Standard
Release 5.0 30 May 2007