Flushing the heat exchanger 
An LC0~LC9 or "00" diagnos c code indicates the unit is beginning to lime up and must be flushed.  Failure to 
flush the appliance will cause damage to the heat exchanger.  Damage caused by lime build‐up is not covered by 
the unit's warranty.  Rinnai strongly recommends installa on of isola on valves to allow for flushing of the heat 
exchanger. 
1.  Disconnect electrical power to the water heater. 
2.  Close the shutoff valves on both the hot water and 
cold water lines (V3 and V4). 
3.  Connect pump outlet hose (H1) to the cold water 
line at service valve (V2). 
4.  Connect drain hose (H3) to service valve (V1). 
5.  Pour 4 gallons of undiluted virgin, food grade, white 
vinegar into pail. 
6.  Place the drain hose (H3) and the hose (H2) to the 
pump inlet into the cleaning solu on. 
7.  Open both service valves (V1 and V2) on the hot 
water and cold water lines. 
8.  Operate the pump and allow the vinegar to circulate 
through the water heater for at least 1 hour at a rate 
of 4 gallons per minute (15.1 liters per minute). 
9.  Turn off the pump. 
10.  Rinse the vinegar from the water heater as follows: 
a.  Remove the free end of the drain hose (H3) from 
the pail.  Place in sink or outside to drain. 
b. Close service valve, (V2), and open shutoff valve, 
(V4).  Do not open shutoff valve, (V3). 
c.  Allow water to flow through the water heater for 
5 minutes. 
d.  Close shutoff valve (V4).  When unit has finished 
draining remove the in‐line filter at the cold water 
inlet and clean out any residue.  Place filter back 
into unit and open valve (V4). 
e.  Close service valve, (V1), and open shutoff valve, 
(V3). 
11.  Disconnect all hoses. 
12.  Restore electrical power to the                                  
water heater. 
Following flush procedure call 
technical assistance (1‐800‐621‐
)
9419
for PCB reset informa on. 
 
3/4" Ball Valve
3/4" Union
Check Valve
Pressure Relief Valve
H3
H2
Circulating Pump
VC Series Manual 
KEY
Pressure Regulator
Circulating Pump
Boiler Drain Valve
S
Solenoid Valve
 
Rinnai
Water Heater
V2
V1
V4
V3
H1