Siemens SIMATIC NET SCALANCE W734-1 Operating Instructions Manual page 10

Industrial wireless lan
Hide thumbs Also See for SIMATIC NET SCALANCE W734-1:
Table of Contents

Advertisement

Security recommendations
Protocol
SSH
TELNET
HTTP
HTTPS
SNTP
NTP
SNMP
PROFINET
Syslog
EtherNet/IP
DHCP
RADIUS
TFTP
10
Port number
Port status
TCP/22
Open (when config‐
ured)
TCP/23
Open (when config‐
ured)
TCP/80
Open (when config‐
ured)
TCP/443
Open (when config‐
ured)
UDP/123
Open (when config‐
ured)
UDP/161
Open (when config‐
ured)
UDP/34964,
Open
UDP/49154,
49155
UDP/514
Open (when config‐
ured)
TCP/44818,
Open (when config‐
UDP/
ured)
2222,44818
UDP/67,68
Open (when config‐
ured)
UDP/
Open (when config‐
1812,1813
ured)
UDP/69
Open (when config‐
ured)
Factory setting of the
port
Open
Open
Open
Open
Closed
Open
Open
Open
Open
Closed
Closed
Closed
SCALANCE W774-1 /W734-1
Operating Instructions, 09/2017, C79000-G8976-C325-09
Authentication
Yes
Yes
Yes
Yes
No
Yes
No
No
No
No
No
No