Forced Cooling Operation; C Heat Operation; Economy Operation - Fujitsu AGYG12KVCA Service Manual

Hide thumbs Also See for AGYG12KVCA:
Table of Contents

Advertisement

7-3. Forced cooling operation

The outdoor unit may not operate depending on the room temperature.
When FORCED COOLING OPERATION button is pressed more than 10 seconds, forced cooling
operation starts as shown in the table below.
Operation mode
Fan mode
Timer mode
Setting temperature
Vertical airflow direction louver setting
SWING
ECONOMY
• During the forced cooling operation, it operates regardless of room temperature sensor.
• Operation LED and timer LED blink at the same time during the forced cooling operation.
They blink for 1 second ON and 1 second OFF on both operation LED and timer LED (same as
test operation).
By performing one of the following action, test operation will be canceled:
• Pressing the remote controller START/STOP button
• Pressing FORCED COOLING OPERATION button for 3 seconds
• 60 minutes passed after starting forced cooling operation
NOTE: When HEAT operation is selected on the remote controller during forced cooling operation,
heating test run will begin in about 3 minutes.
7-4. 10 °C HEAT operation
10 °C HEAT operation performs as below setting when pressing 10 °C HEAT button.
Operation mode
Setting temperature
Fan mode
LED display
Defrost operation

7-5. ECONOMY operation

The ECONOMY operation starts by pressing ECONOMY button on the remote controller.
The ECONOMY operation is almost the same operation as below settings.
Mode
Target temperature
7-3. Forced cooling operation
Continuous (no timer setting available)
Cooling/Dry
Setting temperature +1°C
- (04-26) -
Cooling
HIGH
24°C
Standard
Off
Off
Heating
10°C
AUTO
Economy
Operate as normal
Heating
Setting temperature -1°C
7. Various control

Advertisement

Table of Contents
loading

This manual is also suitable for:

Agyg09kvcaAgyg14kvcaAoyg09kvcaAoyg12kvcaAoyg14kvca

Table of Contents