Troubleshooting - Lincoln Electric Aspect 230 DC Operator's Manual

Table of Contents

Advertisement

ASPECT
®
230 DC

TROUBLESHOOTING

HOW TO USE TROUBLESHOOTING GUIDE
WARNING
Service and Repair should only be performed by Lincoln
Electric Factory Trained Personnel. Unauthorized repairs
performed on this equipment may result in danger to the
technician and machine operator and will invalidate your
factory warranty. For your safety and to avoid Electrical
Shock, please observe all safety notes and precautions
detailed throughout this manual.
This Troubleshooting Guide is provided to help you locate and
repair possible machine malfunctions. Simply follow the three-
step procedure listed below.
Error
Description
Code
01
Input voltage too low
02
Input voltage too high
03
Incorrect input
connection
04
Primary side voltage
lock out
06
Inverter voltage lock out Indicates that an Internal Voltage fault
Conn Err Connection Error
10
Fan fault
11
Water Cooler Fault
12
Water Cooler Presence
Fault
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Lincoln Authorized Service Facility for technical troubleshooting assistance before you proceed.
WWW.LINCOLNELECTRIC.COM/LOCATOR
Observe all Safety Guidelines detailed throughout this manual
Possible Cause
Input voltage is less than 90VAC, or drops
below 90VAC under load
Input voltage is higher than 500VAC or
spikes above 500VAC during load
Input voltage not configured correctly
Indicates that an internal auxiliary voltage
fault condition is detected.
condition is detected.
A communication error between the
control and UI board has occurred.
This error message indicates the fan is not
operating properly. This prevents over
temperature damage.
Insufficient coolant in the cooler, TIG torch
is undersized for application, TIG torch is
pinched, faulty flow sensor in the cooler.
Cooler is not connected to the 9-pin
connector,
Step 1. LOCATE PROBLEM (SYMPTOM).
Look under the column labeled "PROBLEM (SYMPTOMS)". This
column describes possible symptoms that the machine may
exhibit. Find the listing that best describes the symptom that the
machine is exhibiting.
Step 2. POSSIBLE CAUSE.
The second column labeled "POSSIBLE CAUSE" lists the obvious
external possibilities that may contribute to the machine symptom.
Step 3. RECOMMENDED COURSE OF ACTION
This column provides a course of action for the Possible Cause,
generally it states to contact your local Lincoln Authorized Field
Service Facility.
If you do not understand or are unable to perform the
Recommended Course of Action safely, contact your local Lincoln
Authorized Field Service Facility.
Course Of Action
Check the input voltage with and without a load applied,
check the cable size, and fuse size.
Check the input voltage with and without a load applied.
Turn OFF the machine and check the input connections. If
three phase is being applied, ensure the voltage is at
least 185VAC
Indicates that an overload condition occurred. Turn off the
machine, wait one minute and then turn the machine on.
Turn off the machine, wait one minute and then turn the
machine on.
Turn off the machine, wait one minute and then turn the
machine on.
Turn off the machine, wait one minute and then turn the
machine on.
Check the TIG torch for kinks, check the cooler
connections, verify the fluid in the cooler is within the
suggested limits, replace damaged torch, replace torch
with a higher ampacity torch, toggle flow switch on cooler
to remove the error code.
Water cooler was connected/disconnected during
operation. Turn off the machine, connect the cooler, wait
one minute and then turn the machine on.