G. STATUS DISPLAY MODE
Status Display Mode will activate when button B
Figure 47 – Status Mode Screens
Parameter
A: Li or A: GA
b: Fr
C: Lc
d: oP
E: dH
F: Eh
h: In
L:rt
1: PH
2: rh
L:rt
3: rH
4: It
5: IH
J: AG
Table 27 – Status Mode Display Screen Descriptions – NOTE: Shaded Parameters Not Used on This Software Version
Turn the dial
counterclockwise and clockwise to scroll through the displayed parameters. To view parameter details, press the
button at the appropriate screen. Press the
Press the
button again to return to Operation Mode.
To turn on Lock Mode, press the
Off. Press the
button to save the selection and return to the parameters.
Press the
button again to return to Operation Mode.
NOTE: The Control System will not allow the changes if Lock Mode is activated. Lock Mode will have to be turned off before making
further changes.
H. INSTALLER MODE
Installer Mode will activate when button B
Index
Default
1: EH
E0:00
2: cE
OFF
is pressed and held for five seconds at Standby Mode.
Detail
Flow Unit
Fan Speed (RPM)
Lock Mode
OP Temperature
DHW Outlet Temperature
Exhaust Temperature
Inlet Temperature
Running Time
Power Supply Time
Burner Operating Time
Burner Operating Time
Ignition Attempts Number
Ignition Attempts Number
AGM Value Correction
or
buttons to leave the parameter.
button at the C:Lc parameter. Turn the dial
is pressed and held for five seconds while the water heater is powered Off.
Figure 48 – Installer Mode Screens
Parameter
Error History
Clear Error History
Description
Current Flow Unit (Li: Liters/min, GA: Gallons/min)
Current Fan Speed RPM Value
Lock Mode is In Use (ON) or Unused (OFF)
Allows user to lock out any temperature change.
Current Heat Exchanger Operating Temperature
Current DHW Outlet Temperature
Current Exhaust Temperature
Current Inlet Temperature
Display Running Time
Power Supply Time: 100 hour increments
Burner Operating Time: 1 hour increments
Burner Operating Time: 1,000 hour increments
Ignition Attempts Number: 10 times unit displayed
Ignition Attempts Number: 10,000 times unit displayed
AGM Value Correction Range: -50 to 50
Default: 00
counterclockwise and clockwise to scroll On or
Description
Ten Most Recent Error Codes (H0 – H9)
Select "ON" to Clear Error History
Range: ON and OFF
55
WHL-004 REV. 5.26.17